1-888-610-7664

sales@GlobalTestSupply.com

Chat Live

Customer Reviews

Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Model: RAYCI1A50LW

Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)-


Downloads: datasheet

Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Model: RAYCI1A50LW

The CI sensor provides the advantages of infrared temperature measurement in a compact, low cost sensor and can easily replace traditional contact probes with a J-type or K-type thermocouple output, or with a 0-5V output, when integrated into a standard 4-wire system.

The CI sensor provides the advantages of infrared temperature measurement in a compact, low cost sensor and can easily replace traditional contact probes with a J-type or K-type thermocouple output, or with a 0-5V output, when integrated into a standard 4-wire system.

This product has been discontinued. Contact us for more information.


Raytek RAYCI1A50LW Offers

Designed for easy integration into a standard 4-wire system, the CI1A sensor can easily replace traditional contact probes with a J-type thermocouple output. Because the CI unit has the same 50Ω output impedance as a thermocouple, it functions accurately — without offset errors— when used in conjunction with the thermocouple break protection circuitry in most controllers, displays, and transmitters.

Designed to measure target temperatures ranging from 0 to 115°C (32 to 240°F), the CI unit's onboard electronics are protected by a rugged IP 65 (NEMA-4) stainless steel housing, allowing the sensor to function in ambient temperatures to 70°C (160°F) without cooling. With water cooling, the CI sensor can withstand ambient temperatures to 260°C (500°F). Optional cooling jacket must be specified at the time of order.

Can be used in the following applications: blow moulding, bonding, coating, converting, curing, drying, embossing, extrusion, forming, heating, laminating, moulding, ovens, paint drying, paving, printing, and thermo-forming.

Raytek RAYCI1A50LW Specifications

Temperature Range 0 to 115ºC (32 to 240ºF)
Temperature Resolution <0.5°C or 1°F
Accuracy ±2% or ±3ºC (6°F), whichever is greater
System Repeatability ±1% of measured value or ±1°C (2°F), whichever is greater
Response Time (95%) 350 mSec
Emissivity Fixed at 0.95
Spectral Response 7 to 18 µm
Optical Resolution 4:1 (Distance : Spot Size)

 

Click here for complete specifications on the Raytek RAYCI1A50LW

What's included with the Raytek RAYCI1A50LW

  • Infrared sensor
  • Water cooled jacket
  • Two mounting nuts
  • 15m (50 ft.) of high temperature cable
  • Operator’s manual

Customer Reviews for the Raytek RAYCI1A50LW

Ask a question about Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Raytek RAYCI1A50LW Offers

Designed for easy integration into a standard 4-wire system, the CI1A sensor can easily replace traditional contact probes with a J-type thermocouple output. Because the CI unit has the same 50Ω output impedance as a thermocouple, it functions accurately — without offset errors— when used in conjunction with the thermocouple break protection circuitry in most controllers, displays, and transmitters.

Designed to measure target temperatures ranging from 0 to 115°C (32 to 240°F), the CI unit's onboard electronics are protected by a rugged IP 65 (NEMA-4) stainless steel housing, allowing the sensor to function in ambient temperatures to 70°C (160°F) without cooling. With water cooling, the CI sensor can withstand ambient temperatures to 260°C (500°F). Optional cooling jacket must be specified at the time of order.

Can be used in the following applications: blow moulding, bonding, coating, converting, curing, drying, embossing, extrusion, forming, heating, laminating, moulding, ovens, paint drying, paving, printing, and thermo-forming.

Raytek RAYCI1A50LW Specifications

Temperature Range 0 to 115ºC (32 to 240ºF)
Temperature Resolution <0.5°C or 1°F
Accuracy ±2% or ±3ºC (6°F), whichever is greater
System Repeatability ±1% of measured value or ±1°C (2°F), whichever is greater
Response Time (95%) 350 mSec
Emissivity Fixed at 0.95
Spectral Response 7 to 18 µm
Optical Resolution 4:1 (Distance : Spot Size)

 

Click here for complete specifications on the Raytek RAYCI1A50LW

What's included with the Raytek RAYCI1A50LW

  • Infrared sensor
  • Water cooled jacket
  • Two mounting nuts
  • 15m (50 ft.) of high temperature cable
  • Operator’s manual

Ask a question about Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Customer Reviews for the Raytek RAYCI1A50LW

More Raytek Products